Transformer is one of the important electrical equipment in power system, it is similar to power transformer, is used to convert circuit voltage or current. However, the purpose of the power transformer switching voltage and current, is to transfer the power, voltage or current transformer transformation, the purpose of measuring and monitoring circuit voltage or current. In general, power transformer capacity is big, the change of the voltage or current error, transformer capacity is small, the change of the voltage or current error is small. In the measuring circuit, which is used to convert current, the current meter and relay is called a current transformer, power transformer is used to convert voltage, the voltage meter and relay of power transformer is called voltage transformer.
The current transformer of type LCWD1-35 is oil insulated and outdoor product. It is used for metering energy, current and relay protection in electric system up to rated frequency 50Hz or 60Hz and rated voltage 35kV.
Category:Switchgear&HVCTBrand:JGGYElectricModel:LDJ1-35Power:35KVFOBPort:Ningbo/ShanghaiTermsofP
The voltage transformer of the type JDJ(J)2-35 is single has and oil-filled product. It is used for metering electric energy, voltage control and relay protection in the electric system up to rated frequency 50Hz or 60Hz and rated voltage 35kV.
Category:Switchgear&HVCTBrand:JGGYElectricModel:LDJ-10Power:10KVFOBPort:Ningbo/ShanghaiTermsofPy
JDT-27.5 Oil-immersed type single phase AC voltage transformer for the use of measurement and protection in the traction of electrified railway
Category:Switchgear&HVCTBrand:JGGYElectricModel:LFS-10Power:10KVFOBPort:Ningbo/ShanghaiTermsofPy
This type of transformer is applicable to 50 Hz, 35 kV power systems and is used for voltage transformation, electric energy measuring and replaying protection.
Category:Switchgear&HVCTBrand:JGGYElectricModel:LMZB3-10Power:10KVFOBPort:Ningbo/ShanghaiTermsof
This type of transformer is applicable to 50 Hz, 35 kV power systems and is used for voltage transformation, electric energy measuring and replaying protection.
Category:Switchgear&HVCTBrand:JGGYElectricModel:LQJ-10Power:10KVFOBPort:Ningbo/ShanghaiTermsofPy
The classification of the transformer:
According to the principle of classification: can be divided into capacitive voltage transformer and voltage transformer electromagnetic voltage transformer, current transformer are electromagnetic current transformer.
According to the winding insulation medium classification, there are dry, pouring, oil-immersed and inflatable (SF6).
According to use classification: can be divided into two broad categories, voltage transformer, current transformer, can divide again for measuring, protection, special purpose and precise four classes.
According to the installation site classification: can be divided into indoor type and outdoor type two kinds.
According to the number of phase voltage transformer classification: can be divided into two kinds of single-phase, three-phase.
Voltage transformer windings by several categories: duplex winding, three-winding two kinds.
The classification of the current transformer according to the installation method: wear a wall type, support type and loading type 3 kinds.
The classification of the current transformer according to the current ratio: a single variable ratio and changeable than two.
Copyright © 2021 By JGGY Electrical.com