Transformer

Transformer is one of the important electrical equipment in power system, it is similar to power transformer, is used to convert circuit voltage or current. However, the purpose of the power transformer switching voltage and current, is to transfer the power, voltage or current transformer transformation, the purpose of measuring and monitoring circuit voltage or current. In general, power transformer capacity is big, the change of the voltage or current error, transformer capacity is small, the change of the voltage or current error is small. In the measuring circuit, which is used to convert current, the current meter and relay is called a current transformer, power transformer is used to convert voltage, the voltage meter and relay of power transformer is called voltage transformer.

Three-Phase Dry-Type Wound Core Distribution

The three-phase dry-type wound core distribution transformer is a high-efficiency distribution transformer designed for modern power systems.

Single Phase Pad Mounted Transformer

Single-phase pad-mounted transformer is the type with a clamshell cabinet for ease to opening and uninhibited access to connection.

JDX6-35 single phase outdoor voltage transformer 35KV PT

Thevoltagetransformerisasingle-phaseoutdooroilimmersiontypeproducts,applicabletotheratedfrequency50h

Three Phase Pad Mounted Transformer

Three phase pad mounted transformers are designed and manufactured in compliance with all applicable ANSI and DOE2016 standards.

JDZ-3/6/10 Indoor single-phase epoxy resin casting type voltage transformer

3KV6KV10KVIndoorsingle-phaseepoxyresincastingtypevoltagetransformerCategory:Switchgear&HVPTBrand

Single Phase Automatic Voltage Regulator

Single-phase step voltage regulators are tap-changing autotransformers.

JDZ9-3/6/10 Indoor single-phase epoxy resin casting type voltage transformer

3KV6KV10KVIndoorsingle-phaseepoxyresincastingtypevoltagetransformerCategory:Switchgear&HVPTBrand

Three Phase Automatic Voltage Regulator

The Three Phase Step Voltage Regulator adjusts the voltage for each phase by automatically switching between different voltage steps.

JDZ9-3/6/10R3 Indoor single-phase epoxy resin casting type voltage transformer

3KV6KV10KVIndoorsingle-phaseepoxyresincastingtypevoltagetransformerCategory:Switchgear&HVPTBrand

The classification of the transformer:

  1. According to the principle of classification: can be divided into capacitive voltage transformer and voltage transformer electromagnetic voltage transformer, current transformer are electromagnetic current transformer.

  2. According to the winding insulation medium classification, there are dry, pouring, oil-immersed and inflatable (SF6).

  3. According to use classification: can be divided into two broad categories, voltage transformer, current transformer, can divide again for measuring, protection, special purpose and precise four classes.

  4. According to the installation site classification: can be divided into indoor type and outdoor type two kinds.

  5. According to the number of phase voltage transformer classification: can be divided into two kinds of single-phase, three-phase.

  6. Voltage transformer windings by several categories: duplex winding, three-winding two kinds.

  7. The classification of the current transformer according to the installation method: wear a wall type, support type and loading type 3 kinds.