Transformer

Transformer is one of the important electrical equipment in power system, it is similar to power transformer, is used to convert circuit voltage or current. However, the purpose of the power transformer switching voltage and current, is to transfer the power, voltage or current transformer transformation, the purpose of measuring and monitoring circuit voltage or current. In general, power transformer capacity is big, the change of the voltage or current error, transformer capacity is small, the change of the voltage or current error is small. In the measuring circuit, which is used to convert current, the current meter and relay is called a current transformer, power transformer is used to convert voltage, the voltage meter and relay of power transformer is called voltage transformer.

Single Phase Oil Type Distribution Transformer

Single-phase pole mounted transformer server as distribution transformer in the distribution network of decentralized power supply, it has many advantages, such as reducing the length of low-voltage distribution line losses and improving the power supply efficiency.

LZZBJ9-12 indoor 12KV current transformer

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZBJ9-12Power:12KVFOBPort:Ningbo/ShanghaiTermso

3 Phase Oil Type Distribution Transformer

Oil-immersed distribution transformers are widely used in distribution network, power supply and distribution systems of industrial & mining enterprises.

LZZBJ9-35Q indoor current transformer 35kv CT

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZBJ9-35QPower:35-40KVFOBPort:Ningbo/ShanghaiTe

3 Phase Dry Type Distribution Transformer

Cast resin dry type transformer is a type of SC(B) dry transformer with epoxy resin, which is a widely used in many fields. Its winding surface consists of high-quality protective material that forms the cover.

LZZBJ18-10 current transformer is of epoxy resin vacuum casting fully-enclosed support-type

current transformer is of epoxy resin vacuum casting fully-enclosed support-type

Amorphouse Alloy Transformer

Amorphous Alloy Transformer is a type of power transformer with low loss and high energy efficiency. This type of transformer uses iron-based amorphous metal as its core.

LZZJ-10Q current transformer 10KV

Category:Switchgear&HVCTBrand:JGGYElectricModel:LZZJ-10QPower:10KVFOBPort:Ningbo/ShanghaiTermsof

Three-Phase Oil-Immersed Coil-Core Distribution Transformer

The transformer, with its new 3D rolled iron core design, offers significant advantages over laminated and flat rolled iron core transformers.

JDJ2-35 Outdoor single phase voltage transformer oil immersed MV 35KV PT

Thisseriesforthesinglephasevoltagetransformeroilproducts,suitableforratedfrequency50hzor60hz,ratedvo

The classification of the transformer:

  1. According to the principle of classification: can be divided into capacitive voltage transformer and voltage transformer electromagnetic voltage transformer, current transformer are electromagnetic current transformer.

  2. According to the winding insulation medium classification, there are dry, pouring, oil-immersed and inflatable (SF6).

  3. According to use classification: can be divided into two broad categories, voltage transformer, current transformer, can divide again for measuring, protection, special purpose and precise four classes.

  4. According to the installation site classification: can be divided into indoor type and outdoor type two kinds.

  5. According to the number of phase voltage transformer classification: can be divided into two kinds of single-phase, three-phase.

  6. Voltage transformer windings by several categories: duplex winding, three-winding two kinds.

  7. The classification of the current transformer according to the installation method: wear a wall type, support type and loading type 3 kinds.

  8. The classification of the current transformer according to the current ratio: a single variable ratio and changeable than two.