Transformer

Transformer is one of the important electrical equipment in power system, it is similar to power transformer, is used to convert circuit voltage or current. However, the purpose of the power transformer switching voltage and current, is to transfer the power, voltage or current transformer transformation, the purpose of measuring and monitoring circuit voltage or current. In general, power transformer capacity is big, the change of the voltage or current error, transformer capacity is small, the change of the voltage or current error is small. In the measuring circuit, which is used to convert current, the current meter and relay is called a current transformer, power transformer is used to convert voltage, the voltage meter and relay of power transformer is called voltage transformer.

3 phase recloser distribution automation

The JSJW series vacuum recloser consists of integrated terminals, current transformers, permanent magnet actuators, and recloser controllers.

JDZ10 3KV 6KV 10KV Indoor single-phase epoxy resin casting type voltage transformer

3KV6KV10KVIndoorsingle-phaseepoxyresincastingtypevoltagetransformerCategory:Switchgear&HVPTBrand

Chinese box type Prefabricated Substation

Chinese box type transformer substation is different from American box type transformer substation and European box type transformer substation.

ZGS series prefabricated substation(American type box substation)

ZGS series prefabricated substation is suitable for 7.2KV and 12KV ring network power supply, dual power supply or terminal power supply system.

JDZW-3/6/10 Outdoor single-phase epoxy resin casting type voltage transformer

3KV6KV10KVOutdoorsingle-phaseepoxyresincastingtypevoltagetransformerCategory:Switchgear&HVPTBran

YBW-12/0.4 Outdoor combined substation (European box type substation)

YBW series prefabricated substation is a combination of high-voltage electrical equipment, transformer low-voltage electrical equipment, etc.

JDZW-35 Outdoor voltage transformer 35kv

Thevoltagetransformerforoutdoor(SwitzerlandCiba,CW5837)epoxyresincasting,voltagetransformerisfullyen

JP type low-voltage power distribution reactive power compensation integrated cabinet

product description JP type low-voltage power distribution reactive power compensation integrated cabinet is a new type of outdoor power distribution reactive power compensation integrated cabinet designed in accordance with the principles of safety, economy, reasonableness and reliability.

JDZX9-35 Indoor single-phase epoxy resin casting type voltage transformer

Theseriesvoltagetransformersuitableforratedfrequency50hzor60hz,ratedvoltage35kvindoorunitofelectrici

The classification of the transformer:

  1. According to the principle of classification: can be divided into capacitive voltage transformer and voltage transformer electromagnetic voltage transformer, current transformer are electromagnetic current transformer.

  2. According to the winding insulation medium classification, there are dry, pouring, oil-immersed and inflatable (SF6).

  3. According to use classification: can be divided into two broad categories, voltage transformer, current transformer, can divide again for measuring, protection, special purpose and precise four classes.

  4. According to the installation site classification: can be divided into indoor type and outdoor type two kinds.

  5. According to the number of phase voltage transformer classification: can be divided into two kinds of single-phase, three-phase.

  6. Voltage transformer windings by several categories: duplex winding, three-winding two kinds.

  7. The classification of the current transformer according to the installation method: wear a wall type, support type and loading type 3 kinds.

  8. The classification of the current transformer according to the current ratio: a single variable ratio and changeable than two.


Leave A Message

Copyright © 2021 By JGGY Electrical.com