Product overview
FZN25, JLFZRN25 vacuum load switches and combined electrical appliances are suitable for load control and short-circuit protection in three-phase AC 50Hz ring network or terminal power supply and industrial electrical equipment. The load switch switches the load, closed-loop current, no-load transformer and cable charging current. . Combination appliances can break any current up to the rated short-circuit current. It adopts direct-acting isolation fracture and vacuum arc extinguishing chamber linkage. Available in manual and electric functions.
Due to the unique transmission structure design of FZN25 and FZRN25, the arc extinguishing chamber only withstands high voltage at the moment of closing and opening, so it is small in size and light in weight.
FZN25 and FZRN25 can realize one-time operation of isolation fracture and arc extinguishing chamber fracture.
FNZ25 and FZRN25 have a grounding valve that is linked to the grounding switch between the static contact and the moving contact conductive tube, which not only ensures safety but also facilitates maintenance.

12KV air LBS load break switch MV electric by manual ISARC series
indoor HV air load break switch is a 3-phase AC 50Hz 36kV indoor switchgear equipment.
Russia indoor 10KV load break switch with fuse ВНА-Л-10/630
ABB similar FN18-12 series 12KV Indoor load break switch LBS
ABB NALF 12KV load break switch FN18-12 LBS with fuse holder
manufacturer FN7 12KV LBS Indoor load break switch with fuse holder for RMU
Indoor AC High/Medium Voltage Vacuum Load Break switch 12KV LBS
FZN25/FZRN25 type indoor 12KV HV MV vacuum load break switch LBS
FN5-12D Indoor LBS 12KV MV air load break switch for RMU
ABB NAL/FN18-24D 24KV LBS load break switch indoor air
FN7-24D 24KV LBS Medium voltage overload switch load break switch with earth switch
indoor HV air load break switch is a 3-phase AC 50Hz 12kV indoor switch equipment.
FN5-24 series 24KV LBS MV load break switch with earth switch or fuse holder for air RMU
ABB type NALF 24KV FN18-24R LBS load break switch
12KV LBS high voltage vacuum load break switch by motor
12KV HV load break switch and fuse combination electrical appliance
Medium Voltage Vacuum Load Break switch HV MV LBS 36-40KV Indoor AC
FKN12 24KV air load break switch indoor MV LBS
FN7-24R AC and HV indoor air load break switch 24KV MV LBS manufacturer
The FLW36-12/24/40.5 outdoor column-mounted negative switch is suitable for breaking and closing load currents and overload currents in power systems rated 12/24/40.5kV, rated current 630A, 50/60Hz.
FCR21-40.5RD (Embedded pole) indoor high voltage ac vacuum load break switch + fuse combination, suitable for AC 50Hz, rated 40.5kV power system, Photovoltaic, New energy, solar energy,
FN7-12D 12KV LBS indoor Medium voltage load break switch with earthing switch
ABB NAL series 12KV LBS medium voltage load break switch for RMU similar as
Russia ВНА-10 Indoor 10KV Load break switch with earch switch VNA-L-10/630-20zp
"FKN12A-12D series compressed air load switch can switch load current and overload current FKRN12A-12D series compressed air load switch-fuse combination appliance can switch load current, overload current, and break line short-circuit current"
FZN25, JLFZRN25 vacuum load switches and combined electrical appliances are suitable for load control and short-circuit protection in three-phase AC 50Hz ring network or terminal power supply and industrial electrical equipment.
FZN25-12DG/630-20 and FZN25-12DG/1250-25 series vacuum isolation load switch-fuse combination appliances are three-phase high-voltage switching equipment with a rated voltage of 12kV and a rated frequency of 50Hz.
The FZW32-12/40.5kv outdoor high-voltage isolation vacuum load switch (hereinafter referred to as the load switch) is a new generation of high-voltage electrical products produced by our company.
Copyright © 2021 By JGGY Electrical.com