JDC5-66W1 Oil-immersed type voltage transformer

This type of transformer has single-phase three -winding cascade insulating structure, is of outdoor type, it is applicable to neutral point ineffective earthing systems of 50Hz and 66kv,used for voltage, electric energy measuring and relaying protection.

JDC5-66TH Oil-immersed type voltage transformer

This type of transformer has single-phase three -winding cascade insulating structure, is of outdoor type, it is applicable to neutral point ineffective earthing systems of 50Hz and 66kv,used for voltage, electric energy measuring and relaying protection.

JDC5-66GY Oil-immersed type voltage transformer

This type of transformer has single-phase three -winding cascade insulating structure, is of outdoor type, it is applicable to neutral point ineffective earthing systems of 50Hz and 66kv,used for voltage, electric energy measuring and relaying protection.

JDCF-66W1 Oil-immersed type voltage transformer

This type of transformer has single-phase three-winding cascade insulating structure, is of outdoor type, it is applicable to neutral point ineffective earthing systems of 50Hz and 6kv, used for voltage, electric energy measuring and relaying protection.

JDT-55 Oil-immersed type single phase AC voltage transformer for the use of measurement and protection in the traction of electrified railway

JDT-55 Oil-immersed type single phase AC voltage transformer for the use of measurement and protection in the traction of electrified railway

JDJ(J)2-35 Voltage transformer type

The voltage transformer of the type JDJ(J)2-35 is single has and oil-filled product. It is used for metering electric energy, voltage control and relay protection in the electric system up to rated frequency 50Hz or 60Hz and rated voltage 35kV.

JDT-27.5 Oil-immersed type single phase AC voltage transformer for the use of measurement and protection in the traction of electrified railway

JDT-27.5 Oil-immersed type single phase AC voltage transformer for the use of measurement and protection in the traction of electrified railway

JD2-35W Oil-immersed type voltage transformer

This type of transformer is applicable to 50 Hz, 35 kV power systems and is used for voltage transformation, electric energy measuring and replaying protection.

JDJ2-35GYW Oil-immersed type voltage transformer

This type of transformer is applicable to 50 Hz, 35 kV power systems and is used for voltage transformation, electric energy measuring and replaying protection.

JDJ2-35 Outdoor single phase voltage transformer oil immersed MV 35KV PT

Thisseriesforthesinglephasevoltagetransformeroilproducts,suitableforratedfrequency50hzor60hz,ratedvo