JGGY Electrical (jggyelectrical.com) was established in 2007, specializing in the supply and manufacturing medium voltage electric Vacuum circuit Breaker, MV switch, Load break switch, Air-insulated switchgear, Disconnector, Cutout fuse, Surge Arrester, etc.

Over the years, JGGY has been successfully used in important fields such as electric power, communications, chemicals, mining, metallurgy, transportation, petroleum, and railways.

Feel free to contact us for a quotation or click on the products you are interested in to view the details.

ZW20F-12 Series Outdoor AC high voltage boundary vacuum circuit breaker

The FZW28-12 series outdoor AC high-voltage demarcation vacuum load switch is suitable for outdoor three-phase AC power distribution systems with a rated voltage of 12KV and a rated frequency of 50H.

FZW28-12 Series Outdoor AC high voltage boundary vacuum load switch

FZW28-12 series outdoor AC high-voltage boundary vacuum load switch is suitable for outdoor three-phase AC power distribution systems with a rated voltage of 12KV and a rated frequency of 50Hz. It is used to open and close load currents and close short-circuit currents.

ZW32-12 Series Outdoor AC high voltage vacuum circuit breaker

The ZW32-12 outdoor AC high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is an outdoor power distribution equipment with a rated voltage of 12kV and a three-phase AC 50Hz.

ZW32Y-12 Series outdoor AC high voltage prepaid vacuum circuit breaker

ZW32Y-12 outdoor AC high-voltage prepaid vacuum circuit breaker is suitable for use as prepaid high-voltage metering in power systems with three-phase AC 50Hz and rated power 12kV.

ZW43-12 Series Outdoor high voltage vacuum circuit breaker

ZW43-12 outdoor high-voltage vacuum circuit breaker is a miniaturized product of ZW32 circuit breaker.

ZW32-24 Series Outdoorhigh voltage vacuum circuit breaker

ZW32-24 outdoor high-voltage vacuum circuit breaker (hereinafter referred to as the circuit breaker) is an outdoor power distribution equipment with a rated voltage of 24kV and three-phase AC 50Hz.

ZW32-40.5 Series outdoor AC high voltage boundary vacuum circuit breaker

ZW32-40.5 outdoor AC high-voltage demarcation vacuum circuit breaker is mainly composed of integrated solid-sealed poles, current transformers, operating mechanisms and boxes.

ZW7-40.5 Series Outdoor high voltage vacuum circuit breaker

ZW7-40.5 series outdoor high-voltage vacuum circuit breaker (hereinafter referred to as "circuit breaker") is used in AC 50Hz, 40.5kV three-phase power systems to divide and combine load current, overload current and short-circuit current.

ZW17-40.5 Series outdoorhigh-voltage vacuum circuit breakers

ZW17-40.5 outdoor high-voltage vacuum circuit breaker is an outdoor high-voltage electrical equipment with three-phase AC 50Hz and rated voltage 40.5KV.

ZW30A-40.5 Series outdoor high-voltage vacuum circuit breakers

ZW30A-40.5 is a three-phase AC 50HZ high-voltage switchgear. It is mainly used for the control and protection of 40.5kv power transmission and transformation systems.

JGGY Electrical adopts a modern production mode, has a group of experts and technicians who have been engaged in the production of electric vacuums and switch for many years. 80% of the high-voltage parts are designed and processed by itself, and it has obtained a number of invention patents every year. All aspects of production and management strictly implement and implement ISO9001 standards, and a corporate office information platform network has been established. CAD and CAM software technology applications are adopted from the whole process of product design, research and development and quality inspection, which greatly reduces product development and production cycle.