What is a MV Load Break Switch (LBS)?

What is a MV Load Break Switch (LBS)?

 

A load break switch (LBS) is a device that ensures the on-load making, breaking and safe disconnection of medium-voltage circuits.

 

The LBS is an air load break switch with mains fuses. A striker is incorporated into the unit, a feature not found in conventional load break switches. The striker is a trip mechanism that operates when the fuse blows. When this happens, the striker opens all 3 poles simultaneously.

 

What is the Advantages of Load break switch?

 

  • Cheaper as compare to 2 pole structure

  • Safer

  • Protection provided for transformer (HRC fuses are provided for protection purpose)

  • Very easy to switch On & Off the supply


What is the LBS feature?

 

  • Excellent arc extinguishing characteristics.

The arc extinguishing system adopts the gas cooling method. This results in less contact wear than comparable oil-immersed models, ensuring longer service life and lower maintenance costs.

 

  • Lightweight and compact design.

Load break switch and fuse integrated in one body, ideal for H.V. cubicle or metal switchgear assembly applications.

 

  • High Current Limiting Power Fuses.

Model LBS is equipped with power fuses to ensure accurate and uniform breaking performance.

 

  • the first cost of the economy

The use of these fuses eliminates the need for a circuit breaker with a trip mechanism, thus reducing initial installation costs.

 

  • Safety Fuse Replacement

The fuse can be easily replaced or changed to a different rating and is very safe.

 

  • Shunt trip mechanism

The trip mechanism can be connected to LBS and LB with 100 and 200 amp ratings. It can be tripped remotely.

 

  • fuse indicator

LBS and LB 400 to 1500 amp rated switches can be equipped with a blown indicator limit switch for remote indication.

 

  • auxiliary contact

All of these switches can be connected to a 2NO+2NC 15 amp switch.

 

  • Motor drive types available

Standard version is used for joystick operation. Motor-driven versions are also available. For more information, please contact JGGY.

 

Load break switches, usually with a spring mechanism for turning the power on and off, however, vacuum circuit breakers are also available as an option. Of course, the option with a vacuum circuit breaker is more expensive. The choice between the two is entirely up to the client. Load switches with vacuum circuit breakers are a more reliable option.

 

Load switches with spring mechanisms are generally protected by fuses. Therefore, every time a failure occurs, the fuse needs to be replaced. On the other hand, if you use a load break switch with a vacuum circuit breaker, we just need to open the breaker.

 

The grounding earth switch also provides a load break switch, which helps ground the charge, which may be present even after the switch is turned off.

 

JGGY has the following model:

FN7 series, 12kv FN7, 24KV FN7, 36KV FN7, FN7-12, FN7-24, FN7-36

FN5 series, 12kv FN5, 24KV FN5, 36KV FN5, FN5-12, FN5-24, FN5-36

FKN12/FKRN12 series, FKN12-12, FKN12-24, FKN12-36, 12KV FKN12, 24KV FKN12, 36KV FKN12, FKRN12-12, FKRN12-24, FKRN12-36, 12KV FKRN12, 24KV FKRN12, 36KV FKRN12

ISARC series, 12KV ISARC, 24KV ISARC, 36KV ISARC,

FN18 series, FN18-12, FN18-24, FN18-36, 12KV FN18, 24KV FN18, 36KV FN18


Ms Miya: sales@jggyelectrical.com

Whatsapp: +86 181 0679 6660

 


Leave A Message

Copyright © 2021 By JGGY Electrical.com