Products

JGGY Electrical (jggyelectrical.com) was established in 2007, specializing in the supply and manufacturing medium voltage electric Vacuum circuit Breaker, MV switch, Load break switch, Air-insulated switchgear, Disconnector, Cutout fuse, Surge Arrester, etc.

Over the years, JGGY has been successfully used in important fields such as electric power, communications, chemicals, mining, metallurgy, transportation, petroleum, and railways.

Feel free to contact us for a quotation or click on the products you are interested in to view the details.

FZW32-12 outdoor high voltage isolating 12KV vacuum break load switch LBS

It composed of disconnector, vacuum interrupter and operating mechanism and other parts.

JGSXV-12 Under isolating circuit breaker for SF6 Free switchgear 12kV

Under isolating circuit breaker for SF6 Free switchgear 12kV

Outdoor Pole-mounted SF6 gas insulated load break switch LBS ceramic bushing

Outdoor Pole-mounted SF6 gas insulated load break switch LBS ceramic bushing

outdoor SF6 LBS sectionalizer insulated load break switch

outdoor SF6 LBS sectionalizer insulated load break switch, ceramic bushing - molded cable outlet

FL(R)N36 24KV Indoor AC High Voltage SF6 LBS Load Break Switch

24KV Indoor AC MV SF6 LBS Load Break Switch, suitable for protecting the 10kV, 24kV and 35kV power system's on load situation

VS1 12KV Indoor VCB vacuum circuit breaker

Indoor high voltage vacuum circuit breaker (circuit breaker) is suitable for indoor switchgear of 12kv power system

FZW32-40.5 outdoor AC high voltage disconnect vacuum load break switch 36-40KV

36-40KV outdoor LBS AC high voltage disconnect vacuum load break switch

ZW20 High Voltage MV 12KV VCB Vacuum Circuit Breakers with the controller

with controller, distribution automation system,and can raliably and effectively complete the recloser function of traditional.

VSG-12 indoor high voltage vacuum circuit breaker 12KV MV VCB

for 12KV power system indoor switching equipment, as power grid equipment, industrial and mining enterprises power design protection and control unit

ZW32-12 outdoor medium voltage vacuum circuit breaker recloser controller 12KV by motor

ZW32-12 outdoor medium voltage vacuum circuit breaker recloser controller 12KV by motor

JGGY Electrical adopts a modern production mode, has a group of experts and technicians who have been engaged in the production of electric vacuums and switch for many years. 80% of the high-voltage parts are designed and processed by itself, and it has obtained a number of invention patents every year. All aspects of production and management strictly implement and implement ISO9001 standards, and a corporate office information platform network has been established. CAD and CAM software technology applications are adopted from the whole process of product design, research and development and quality inspection, which greatly reduces product development and production cycle.

Leave A Message